Sign In | Join Free | My vivirlatino.com
vivirlatino.com
Jackwell Limited
Jackwell Limited Specialized in kinds of PARTS since 1985, Engine spare parts !
Home > Genset Diesel Generator >

2306C-E14TAG2 Genset Diesel Generator

2306C-E14TAG2 Genset Diesel Generator

Brand Name : Perkins
Model Number : JPP400E1
Certification : CE/RoHs/ISO9001
Place of Origin : China
MOQ : 20-30 pieces
Price : Negotiable
Payment Terms : L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability : 500 pieces per Month
Delivery Time : 3-5 days on receipt of official sales contract
Packaging Details : Standard plywood and wood package.the actual package size against goods size and handle requires.
Port : HongKong or ShenZhen,ShangHai,Dalian as required
Contact Now

1, Generating Set Model:P400E1

2, Engine Make & Model:Perkins 2306C-E14TAG2

3, Circuit Breaker Type:3 Pole MCCB

4, Frequency:50 Hz / 60 Hz

5, Engine Speed:1500 rpm / 1800 rpm

6, Cooling Method: Water

7, Governing Type: Electronic

8, Output Type: AC Three Phase


Perkins 2306C-E14TAG2 Genset Diesel Generator


Output Ratings


Generating Set ModelP400E1
380-415V, 50 Hz400.0 kVA / 320.0 kW
480V, 60 Hz438.0 kVA / 350.4 kW
  • Refer to ratings definitions on page

Ratings at 0.8 power factor.

Technical Data

Engine Make & Model:

Perkins 2306C-E14TAG2

Alternator Model:

LL6014D

Base Frame Type:

Heavy Duty Fabricated Steel

Circuit Breaker Type:

3 Pole MCCB

Frequency:

50 Hz 60 Hz

Engine Speed: RPM

1500 1800

Fuel Tank Capacity: litres (US gal)

820 (216.6)

Fuel Consumption: - l/hr (US gal/hr)

- -

Fuel Consumption: P400E1 l/hr (US gal/hr)

85.1 (22.5) 91.3 (24.1)

P400E1


Physical Data


Manufacturer: Perkins

Model: 2306C-E14TAG2

No. of Cylinders/Alignment: 6 / In Line

Cycle: 4 Stroke

Induction: Turbocharged Air To Air Charge Cooled

Cooling Method: Water

Governing Type: Electronic

Governing Class: ISO 8528 G2

Compression Ratio: 15.9:1

Displacement: l (cu.in) 14.6 (890.9)

Bore/Stroke: mm (in) 137.0 (5.4)/165.0 (6.5)

Moment of Inertia: kg m² (lb. in²) 3.43 (11721)

Engine Electrical System:

-Voltage/Ground: 24/Negative

-Battery Charger Amps: 70

Weight: kg (lb)

- Dry: 1690 (3726)

- Wet: 1792 (3951)


Air System :


Air Filter Type: Replaceable Element Combustion

Air Flow:m³/min (cfm)

-Standby: 26.8 (946) 41.6 (1469)

- Max. Combustion Air Intake

Restriction: kPa (in H2O) 6.2 (24.9) 6.2 (24.9)

Radiator Cooling Air Flow:m³/min (cfm)

444.0 (15680) 600.0 (21189)

External Restriction to Cooling Air Flow: Pa (in H2O)

188(0.8) 188 (0.8)


Cooling System :


Cooling System Capacity:l (US gal) 47.0 (12.4) 47.0 (12.4)

Water Pump Type: Centrifugal

Heat Rejected to Water & Lube Oil: kW (Btu/min)

-Standby: 134.9 (7672) 153.2 (8712)

- Heat Radiation to Room:kW (Btu/min)

-Standby: 39.0 (2218) 45.3 (2576)

- Radiator Fan Load: kW (hp) 9.0 (12.1) 17.0 (22.8)

Cooling system designed to operate in ambient conditions up to 50°C (122°F).

Contact your local FG Wilson dealer for power ratings at specific site conditions.


Performance :


Engine Speed: RPM 1500 1800

Gross Engine Power: kW (hp)

-Standby: 353.0 (473.0) 393.0 (527.0)

-Prime: 313.0 (420.0) 365.0 (489.0)

BMEP: kPa (psi)

-Standby: 1935.0 (280.7) 1795.0 (260.4)

-Prime: 1716.0 (248.9) 1667.0 (241.8)

Regenerative Power: kW 27.0 39.0


Lubrication System:


Oil Filter Type: Eco, Full Flow

Total Oil Capacity l (US gal): 68.0 (18.0)

Oil Pan l (US gal): 60.0 (15.9)

Oil Type: API CG4 15W-40

Cooling Method: Water


Fuel System


Fuel Filter Type: Eco Replaceable Element Recommended

Fuel: Class A2 Diesel

Fuel Consumption: l/hr (US gal/hr)

110% 100% 75% 50%

Load Load Load Load


P400E1

50 Hz 85.1 (22.5) 64.0 (16.9) 44.5 (11.8)

60 Hz 91.3 (24.1) 70.9 (18.7) 50.1 (13.2)

(based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


Exhaust System


Silencer Type: Level 1

Silencer Model & Qty: SD150 (1) Pressure Drop Across

Silencer System: kPa (in Hg) 0.01 (0.003) 0.06 (0.018)

Silencer Noise Reduction

Level: dB 19 17

Max. Allowable Back

Pressure: kPa (in. Hg) 7.0 (2.1) 7.0 (2.1)

Exhaust Gas Flow:

m³/min (cfm) -Standby: 66.6 (2352) 95.7 (3380)

-Prime: - -

Exhaust Gas Temperature: °C (°F)

m³/min (cfm) -Standby: 494 (921) 389 (731)

P400E1


Alternator Performance Data



Data Item

50 Hz 60 Hz

415/240V

400/230V

230/115V

200/115V

380/220V

220/110V

220/127V

480/277V

240/139V

380/220V

220/110V

240/120V

208/120V

230/115V

440/254V

220/127V


Motor Starting Capability* kVA


882


827


755


976


969


641


754


703


833


Short Circuit Capacity** %


300


300


300


300


300


300


300


300


300


Reactances: Per Unit


Xd X'd X''d


3.130


0.140


0.111


3.370


0.150


0.120


3.730


0.170


0.132


2.780


0.120


0.099


3.070


0.140


0.109


4.900


0.220


0.174


4.090


0.180


0.145


4.420


0.200


0.157


3.650


0.160


0.130


Reactances shown are applicable to prime ratings


  • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

** With optional Permanent Magnet generator or AREP excitation.


Alternator Technical Data


Physical Data Operating Data

Manufacturer: FG WILSON

Overspeed:RPM 2250

Model: LL6014D

Voltage Regulation (steady state) (%): + /- 0.5

No. of Bearings: 1

Wave Form NEMA = TIF: 50

Insulation Class: H

Wave Form IEC = THF: 2.0%

Winding Pitch Code: 2/3 - 6

Total Harmonic Content LL/LN: 4.0%

Wires: 12

Supression is in line with European Standard

Radio Interference: EN61000-6

Ingress Protection Rating: IP23

Radiant Heat: kW (Btu/min)

-50 Hz: 23.0 (1308)

-60 Hz: 24.4 (1388)

Excitation System: SHUNT

AVR Model: R448

P400E1


Technical Data


3 Phase Ratings and Performance at 50 Hz, 1500 RPM

3 Phase Ratings and Performance at 60 Hz, 1800 RPM



Voltage Prime Model Standby Model Voltage Prime Model Standby Model

- P400E1 - P400E1


kVA kW

kVA kW


kVA kW

kVA kW

415/240V

- -

400.0 320.0

480/277V

- -

438.0 350.4

400/230V

- -

400.0 320.0

220/127V

- -

438.0 350.4

380/220V

- -

400.0 320.0

380/220V

- -

437.0 349.6

230/115V

- -

400.0 320.0

240/120V

- -

438.0 350.4

220/127V

- -

400.0 320.0

230/115V

- -

438.0 350.4

220/110V

- -

400.0 320.0

440/254V

- -

438.0 350.4

200/115V

- -

400.0 320.0

220/110V

- -

437.0 349.6




208/120V

- -

438.0 350.4




230/115V

- -

438.0 350.4


Definitions


Standby Rating


These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).

Prime Rating


These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.


Standard Reference Conditions


Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.





Weights and Dimensions


Weights: kg (lb) Dimensions: mm (in)

Net (+ lube oil)

3300 (7275)

Length

3601 (141.8)

Wet (+ lube oil & coolant)

3350 (7385)

Width

1150 (45.3)

Fuel, lube oil & coolant

4043 (8913)

Height

2065 (81.3)



General Data


Documents


A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.


Generating Set Standards


The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, VDE 0530, NEMA MG-1.22.


Warranty


All equipment carries full manufacturer's warranty.



China Customized Inflatable Bumper Ball Game Bubble Adult Grass CE supplier

2306C-E14TAG2 Genset Diesel Generator Images

Inquiry Cart 0
Send your message to this supplier
 
From:
Enter your email please.
To: Jackwell Limited
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0